    Deep Cooled, High Throughput Spectrometer Engine Exemplar HT. This our high-end proven spectrometer workhorse used in the B&W Tek i-Raman series instruments.

    Equipped with multi-stage deep TE cooling technology, the Exemplar HT can handle demanding applications and ensure long exposure times for unparalleled spectral quality. Utilizing custom high-throughput optics, the exceptional back-thinned detector receives more photons than a typical miniature spectrometer, making it ideal for demanding applications such as Raman spectroscopy. Trust in our expertise for your research needs. 

    Choose from available configurations optimized for 532nm and 785nm excitation Raman spectroscopy. 

    Find this product also available in our Research Grade DIY Raman System

    Key Features

    SMART:

    On-board processing including averaging, smoothing, and dark compensation

    SPEED:

    Acquires and transfers more than 140 spectra per second at an integration time of 6.3ms

    SIGNAL TO NOISE RATIO:

    Integration time of 30 minutes will give a SNR better than 540:1

    Additional Features:

    • High Vis and NIR Response
    • 2048 Detector Elements
    • Over 60% QE at 200nm (80% Peak QE)
    • Software-configurable Cooling Temperature (-25° Default)
    • Ultra Low Noise

    Specifications

    Power Input 5V DC @ 9.0A (maximum at startup)
    5V DC @ 4.0A (typical at normal operation)
    Detector Type Back-thinned CCD Array
    Wavelength Range 532nm - 1100nm
    Detector Pixel Format 2048 effective detector elements
    Effective Pixel Size 14μm x ~ 0.9mm
    Spectrograph f/# 2.2
    Spectrograph Optical Layout Dual-Pass transmission
    Dynamic Range 50,000 (typical)
    Digitizer Resolution 16-bit or 65,535:1
    Data Transfer Speed >140 spectra per second at integration time of 6.3ms in burst mode
    Trigger Delay 95ns +/- 20ns (call for timing diagram)
    Readout Speed > 400kHz
    Integration Time 6.3ms, adjustable in 1μs increments
    Aux Port External trigger, 4 digital outputs (2 with shutter control), 2 digital inputs, analog input, analog output and system reset
    Operating Temperature 5°C - 35°C
    Operational Relative Humidity 85% noncondensing
    CCD Cooling Default: -25°C at ambient of 25<°C. (Δ 50°C minimum)
    Weight 7.6 lbs
    Dimensions 8.66in x 7.08in x 5.12in (220mm x 180mm x 130mm)
    Computer Interface USB 3.0 / 2.0
    Operating Systems Windows: 7, 8, 10 (32-bit & 64-bit)

    Applications

    • Raman and Fluorescence Spectroscopy
    • On-line Process Monitoring
    • BioMedical Spectroscopy
    • Gas and Water Analysis